US Healthcare Professionals Click Here

About Promotor PCR Test Kits

Click one of the buttons below to learn more about that particular PCR Test Kit

HBV Quantitative PCR Test Kit (Real-time)

This real-time PCR test kit is developed for quantitative determination of Hepatitis B virus in HBV-infected individuals, with a high sensitivity of 20IU/mL. The detection would contribute to HBV infection diagnosis, treatment decision making as well as viral-load monitoring during the whole course of antiviral therapy.

Advantages and performance

  • High sensitivity: 20 IU/mL
  • High precision: CV ≤1.5%
  • Wide linear range:50-5.0×108 IU/mL
  • Internal quality control: avoid false negative result
  • Specificity: no cross reaction with HAV, HCV, HEV and HIV
  • Package: 32 tests/kit
https://www.aconlabs.com/wp-content/uploads/2018/05/pcr-test-kit-hbv-603x395.png
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif
https://www.aconlabs.com/wp-content/uploads/2018/05/hbv-linearity-817x450.jpg
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif

Linearity (50-5.0×108 IU/mL)

https://www.aconlabs.com/wp-content/uploads/2018/05/hbv-high-sensitivity-817x450.jpg
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif

High sensitivity (20 IU/mL)

HCV Quantitative PCR Test Kit (Real-time)

This real-time PCR test kit is developed for quantitative determination of Hepatitis C virus in HCV-infected individuals, with a high sensitivity of 30IU/mL. The detection would contribute to HCV infection diagnosis, treatment decision making as well as viral-load monitoring during the whole course of antiviral therapy.

Advantages and performance

  • High sensitivity: 30 IU/mL
  • High precision: CV ≤5%
  • Wide linear range:50-1.0×108 IU/mL
  • Internal quality control: avoid false negative result
  • Specificity: no cross reaction with HAV, HBV, HEV and HIV
  • Package: 32 tests/kit
https://www.aconlabs.com/wp-content/uploads/2018/05/pcr-test-kit-hcv-603x395.png
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif
https://www.aconlabs.com/wp-content/uploads/2018/05/hcv-linearity-817x450.jpg

Linearity (50-1.0×108 IU/mL)

https://www.aconlabs.com/wp-content/uploads/2018/05/hcv-high-sensitivity-817x450.jpg

High sensitivity (30 IU/mL)

HPV 16/18 Genotype PCR Test Kit (Real-time)

Human Papillomavirus types 16 and 18 (high risk types) are responsible for about 70% of all cervical cancer cases worldwide. This real-time PCR test kit is developed for qualitative detection of HPV types 16 and 18 in cervical specimens. It can be used jointly with other cervical cancer screening or diagnostics methods, contributing to more accurate medical information and treatment decision. It can also be used in physical examinations to determine high risk- HPV infection.

Advantages and performance

  • Sensitivity: 500 copies/mL
  • High precision: good repeatability
  • Specificity: no cross reaction with CT, UU, NG and other types of HPV Inside extraction reagent provided ≤30min extraction and 1 hour PCR
  • Specimen: cervical cells
  • Package: 32 tests/kit
https://www.aconlabs.com/wp-content/uploads/2018/05/pcr-test-kit-hpv-16-18-603x395.png
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif
https://www.aconlabs.com/wp-content/uploads/2018/05/hpv-16-18-precision-a-817x373.jpg

A

https://www.aconlabs.com/wp-content/uploads/2018/05/hpv-16-18-precision-b-817x373.jpg

B

Precision
A: Amplification curves of replicates with concentration of 5000 copies/mL
B: Amplification curves of replicates with concentration of 50000 copies/mL

HPV Genotyping PCR RDB Test Kit

This PCR test kit is developed for qualitative detection of 25 types of HPV in cervical specimens. The test utilizes PCR technology to amplify target DNA first and then employ revers dot blot (RDB) technology to determine the presence or absence of the 25 types, which include 14 high risk genotypes: 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 68, and 73; 3 suspected high risk genotypes:26, 53 and 66; 8 low risk genotypes: 6, 11, 40, 42, 43, 44, 81, and 83. It would provide a complete set of HPV-infection information for subsequent diagnostics and treatment decision making.

Advantages and performance

  • Identification of 25 genotypes in one test
  • Specificity: no cross reaction with CT, UU, NG and other types of HPV
  • Coincidence rate: 99.5% with the main stream products in the market inside extraction reagent provided ≤30min extraction & 2.5 hours PCR & 2 hours hybirdization
  • Specificity: no cross reaction with CT, UU, NG and other types of HPV Inside extraction reagent provided ≤30min extraction and 1 hour PCR
  • Specimen: cervical cells
  • Package: 24 tests/kit
https://www.aconlabs.com/wp-content/uploads/2018/05/pcr-test-kit-hpv-genotyping-603x395.png
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif
https://www.aconlabs.com/wp-content/uploads/2018/05/hpv-genotyping-charts-1000x679.jpg
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif

Directly read by eyes

TB PCR Test Kit (Real-time)

This real-time PCR test kit is developed for the qualitative detection of mycobacterium tuberculosis viral DNA in human sputum specimens. It can be used jointly with other diagnostics methods, contributing to final diagnosis of TB infection.

Advantages and performance

  • Sensitivity: 10 bacteria/mL
  • High precision: CV ≤5%
  • Specificity: no cross reaction with UU, MP and CP inside extraction reagent provided ≤30min extraction and 1 hour PCR
  • Specimen: sputum
  • Package: 32 tests/kit
https://www.aconlabs.com/wp-content/uploads/2018/05/pcr-test-kit-tb-603x395.png
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif
https://www.aconlabs.com/wp-content/uploads/2018/05/tb-sensitivity-817x381.jpg
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif

Sensitivity: 10 bacteria per mL

https://www.aconlabs.com/wp-content/uploads/2018/05/tb-precision-817x387.jpg
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif

Precision

HLA-B27 PCR Test Kit (Real-time)

HLA-B27 (Human Leukocyte Antigen B27) DNA in whole blood can be determined using nucleic acid amplification or signal amplification technologies. This PCR test towards potential patients would serve as an assistant means to early diagnose AS and related diseases as well as prevent them from further deterioration.

Advantages and performance

  • Sensitivity: 2.5ng target DNA/μL
  • High precision: CV ≤5%
  • Specificity: no cross reaction with other subtypes of HLA genes internal control included to avoid false result inside extraction reagent provided ≤30min extraction and 1 hour PCR
  • Specimen: whole blood
  • Package: 32 tests/kit
https://www.aconlabs.com/wp-content/uploads/2018/05/pcr-test-kit-hla-b27-603x395.png
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif
https://www.aconlabs.com/wp-content/uploads/2018/05/hla-b27-sensitivity-817x281.jpg
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif

Sensitivity: 2.5ng/μL

https://www.aconlabs.com/wp-content/uploads/2018/05/hla-b27-precision-817x281.jpg
https://www.aconlabs.com/wp-content/uploads/2016/10/spacer.gif

Precision

Contact Us