US Healthcare Professionals Click Here

Thyroid

EIA Kits

About Foresight® Thyroid EIA Kits

Click one of the buttons below to learn more about that particular EIA Kit

Free T3

Quantitative detection of Free Triiodothyronine (T3) in serum

https://www.aconlabs.com/wp-content/uploads/2017/02/I231-3051-Foresight-CE-Free-T3.jpg
https://www.aconlabs.com/wp-content/uploads/2017/01/1315516088680479497CE.svg_.med_.png

High Quality

• Wide calibration range
• High sensitivity and specificity
• High reproducibility
• Consistent and reliable performance

Easy to Use

• Standardized, color-coded and numbered reagents
• Ready-to-use reagents shorten initial prep time
• Total incubation time: 75 min.

Convenient

• All necessary reagents provided
• Breakaway 8-well strips / 96-microwell plate in re-sealable foil pouch
• Shelf life of 12 months

Product Specifications

Learn more about the Foresight® Free T3 EIA Test Kit

Learn More

Resources

Browse our Resources Library for documents related to the Foresight® Free T3 EIA test kit.

Learn More

Contact Us

Contact ACON Labs regarding the Foresight® Free T3 EIA test kit.

Learn More

Product Specifications

Feature Specifications
Catalog No. I231-3051
Tests per Kit 96
Detection Free Triiodothyronine (T3)
Type of Test Quantitative
Principle Competitive EIA
Specimen Serum
Specimen Volume 50 μL
Specimen Diluent Volume N/A
Neutralization Solution Volume N/A
Conjugate Volume 50 μL
Substrate A/B Volume 50 μL/50 μL
Stop Solution Volume 50 μL
Total Incubation Time 75 min (60/15 min)
Wavelength 450 or 450/630-700 nm
Calibrator Range 0-45.0 pg/mL
Analytical Sensitivity 0.1 pg/mL
Intra-Assay Precision <10.0%
Inter-Assay Precision <15.0%

Resources

Product Brochure

Product brochure for the Foresight® Free T3 EIA test kit.

Package Insert

Package insert for the Foresight® Free T3 EIA test kit.

Free T4

Quantitative detection of Free Thyroxine (T4) in serum

https://www.aconlabs.com/wp-content/uploads/2017/02/I231-3031-Foresight-CE-Free-T4.jpg
https://www.aconlabs.com/wp-content/uploads/2017/01/1315516088680479497CE.svg_.med_.png

High Quality

• Wide calibration range
• High sensitivity and specificity
• High reproducibility
• Consistent and reliable performance

Easy to Use

• Standardized, color-coded and numbered reagents
• Ready-to-use reagents shorten initial prep time
• Total incubation time: 75 min.

Convenient

• All necessary reagents provided
• Breakaway 8-well strips / 96-microwell plate in re-sealable foil pouch
• Shelf life of 12 months

Product Specifications

Learn more about the Foresight® Free T4 EIA Test Kit

Learn More

Resources

Browse our Resources Library for documents related to the Foresight® Free T4 EIA test kit.

Learn More

Contact Us

Contact ACON Labs regarding the Foresight® Free T4 EIA test kit.

Learn More

Product Specifications

Feature Specifications
Catalog No. I231-3031
Tests per Kit 96
Detection Free Thyroxine (T4)
Type of Test Quantitative
Principle Competitive EIA
Specimen Serum/Plasma
Specimen Volume 25 μL
Specimen Diluent Volume N/A
Neutralization Solution Volume N/A
Conjugate Volume 100 μL
Substrate A/B Volume 50 μL/50 μL
Stop Solution Volume 50 μL
Total Incubation Time 75 min (60/15 min)
Wavelength 450 or 450/630-700 nm
Calibrator Range 0-7.4 ng/dL
Analytical Sensitivity 0.06 ng/dL
Intra-Assay Precision <10.0%
Inter-Assay Precision <15.0%

Resources

Product Brochure

Product brochure for the Foresight® Free T4 EIA test kit.

Package Insert

Package insert for the Foresight® Free T4 EIA test kit.

Total T3

Quantitative detection of Total Triiodothyronine (T3) in serum

https://www.aconlabs.com/wp-content/uploads/2017/02/I231-3041-Foresight-CE-Total-T3.jpg
https://www.aconlabs.com/wp-content/uploads/2017/01/1315516088680479497CE.svg_.med_.png

High Quality

• Wide calibration range
• High sensitivity and specificity
• High reproducibility
• Consistent and reliable performance

Easy to Use

• Standardized, color-coded and numbered reagents
• Ready-to-use reagents shorten initial prep time
• Total incubation time: 75 min.

Convenient

• All necessary reagents provided
• Breakaway 8-well strips / 96-microwell plate in re-sealable foil pouch
• Shelf life of 12 months

Product Specifications

Learn more about the Foresight® Total T3 EIA Test Kit

Learn More

Resources

Browse our Resources Library for documents related to the Foresight® Total T3 EIA test kit.

Learn More

Contact Us

Contact ACON Labs regarding the Foresight® Total T3 EIA test kit.

Learn More

Product Specifications

Feature Specifications
Catalog No. I231-3041
Tests per Kit 96
Detection Total Triiodothyronine (T3)
Type of Test Quantitative
Principle Competitive EIA
Specimen Serum
Specimen Volume 50 μL
Specimen Diluent Volume N/A
Neutralization Solution Volume N/A
Conjugate Volume 100 μL
Substrate A/B Volume 50 μL/50 μL
Stop Solution Volume 50 μL
Total Incubation Time 75 min (60/15 min)
Wavelength 450 or 450/630-700 nm
Calibrator Range 0-10 ng/mL
Analytical Sensitivity 0.1 ng/mL
Intra-Assay Precision <10.0%
Inter-Assay Precision <15.0%

Resources

Product Brochure

Product brochure for the Foresight® Total T3 EIA test kit.

Package Insert

Package insert for the Foresight® Total T3 EIA test kit.

Total T4

Quantitative detection of Total Thyroxine (T4) in serum

https://www.aconlabs.com/wp-content/uploads/2017/02/totalt4.png
https://www.aconlabs.com/wp-content/uploads/2017/01/1315516088680479497CE.svg_.med_.png

High Quality

• Wide calibration range
• High sensitivity and specificity
• High reproducibility
• Consistent and reliable performance

Easy to Use

• Standardized, color-coded and numbered reagents
• Ready-to-use reagents shorten initial prep time
• Total incubation time: 75 min.

Convenient

• All necessary reagents provided
• Breakaway 8-well strips / 96-microwell plate in re-sealable foil pouch
• Shelf life of 15 months

Product Specifications

Learn more about the Foresight® Total T4 EIA Test Kit

Learn More

Resources

Browse our Resources Library for documents related to the Foresight® Total T4 EIA test kit.

Learn More

Contact Us

Contact ACON Labs regarding the Foresight® Total T4 EIA test kit.

Learn More

Product Specifications

Feature Specifications
Catalog No. I231-3021
Tests per Kit 96
Detection Total Thyroxine (T4)
Type of Test Quantitative
Principle Competitive EIA
Specimen Serum
Specimen Volume 25 μL
Specimen Diluent Volume N/A
Neutralization Solution Volume N/A
Conjugate Volume 100 μL
Substrate A/B Volume 50 μL/50 μL
Stop Solution Volume 50 μL
Total Incubation Time 75 min (60/15 min)
Wavelength 450 or 450/630-700 nm
Calibrator Range 0-25 μg/dL
Analytical Sensitivity 0.4 μg/dL
Intra-Assay Precision <10.0%
Inter-Assay Precision <15.0%

Resources

Product Brochure

Product brochure for the Foresight® Total T4 EIA test kit.

Package Insert

Package insert for the Foresight® Total T4 EIA test kit.

TSH

Quantitative detection of Thyroid Stimulating Hormone (TSH) in serum or plasma

https://www.aconlabs.com/wp-content/uploads/2017/02/I231-3011-Foresight-CE-TSH.jpg
https://www.aconlabs.com/wp-content/uploads/2017/01/1315516088680479497CE.svg_.med_.png

High Quality

• Wide calibration range
• High sensitivity and specificity
• High reproducibility
• Consistent and reliable performance

Easy to Use

• Standardized, color-coded and numbered reagents
• Ready-to-use reagents shorten initial prep time
• Total incubation time: 80 min.

Convenient

• All necessary reagents provided
• Breakaway 8-well strips / 96-microwell plate in re-sealable foil pouch
• Shelf life of 12 months

Product Specifications

Learn more about the Foresight® TSH EIA Test Kit

Learn More

Resources

Browse our Resources Library for documents related to the Foresight® TSH EIA test kit.

Learn More

Contact Us

Contact ACON Labs regarding the Foresight® TSH EIA test kit.

Learn More

Product Specifications

Feature Specifications
Catalog No. I231-3011
Tests per Kit 96
Detection Thyroid Stimulating Hormone (TSH)
Type of Test Quantitative
Principle Sandwich EIA
Specimen Serum/Plasma
Specimen Volume 50 μL
Specimen Diluent Volume N/A
Neutralization Solution Volume N/A
Conjugate Volume 100 μL
Substrate A/B Volume 50 μL/50 μL
Stop Solution Volume 50 μL
Total Incubation Time 80 min (60/20 min)
Wavelength 450 or 450/630-700 nm
Calibrator Range 0-40 μIU/mL
Analytical Sensitivity 0.078 µIU/mL
Intra-Assay Precision 4.8%
Inter-Assay Precision 9.0%

Resources

Product Brochure

Product brochure for the Foresight® TSH EIA test kit.

Package Insert

Package insert for the Foresight® TSH EIA test kit.

Contact Us

CONTACT DETAILS

24/7 Customer Support

858-875-8038

intl_orders@aconlabs.com

CONTACT FORM

© 2017 ACON Laboratories, Inc. | All Rights Reserved

Sitemap